产品分类

联系我们

深圳市奋华自动化科技有限公司

联系人:高先生

手机:13418972091

邮箱:1027620478@qq.com

          1352556328@qq.com

网址:www.fenhuamv.com

地址:深圳市宝安区福永街道凤凰社区兴业三路2号礼悦智创园A幢305

安阳acA1300-75gm

您的当前位置: 首 页 >> 产品中心 >> BASLER

安阳acA1300-75gm

  • 所属分类:安阳BASLER

  • 型号:acA1300-75gm
  • 点击次数:
  • 发布日期:2018/09/28
  • 在线询价
详细介绍

acA1300-75gm

acA1300-75gm

acA1300-75gm

General Specifications

SpecificationacA1300-75gm

Resolution
(H x V Pixels)

1280 x 1024

Sensor Type

ON Semiconductor®

PYTHON NOIP1SN1300A

Progressive scan CMOS

Global shutter

Optical Size

1/2"

Effective Sensor Diagonal

7.9 mm

Pixel Size (H x V)

4.8 μm x 4.8 μm

Frame Rate

88 fps (at fast sensor readout mode)

81fps (at normal sensor readout mode)

Product Line

ace U

Mono / Color

Mono

Image Data Interface

Fast Ethernet (100 Mbit/s)

Gigabit Ethernet (1000 Mbit/s)

Pixel Formats

See Pixel Format.

Synchronization

Via hardware trigger

Via software trigger

Via free run

Exposure Time Control

Via hardware trigger

Programmable via the camera API

Camera Power Requirements

Power over Ethernet (PoE) 802.3af compliant supplied via Ethernet connector

12–24 VDC supplied via I/O connector

≈3.1 W (typical), ≈3.3 W (max.) when using Power over Ethernet

≈2.7 W (typical), ≈2.9 W (max.) @ 12–24 VDC when supplied via I/O connector

I/O Lines

opto-coupled input line

opto-coupled output line

general purpose I/O (GPIO) line

Lens Mount

C-mount

Size (L x W x H)

42.0 mm x 29 mm x 29 mm (without lens mount or connectors)

60.3 mm x 29 mm x 29 mm (with lens mount and connectors)

Weight

<90 g

Conformity

CE (includes RoHS), UL Listed, FCC, GenICam, GigE Vision, IP30, IEEE 802.3af (PoE), REACH

The EU Declaration of Conformity is available on the Basler website.

Software

Basler pylon Camera Software Suite (version 4.0 or higher)

Available for Windows, Linux x86, Linux ARM, and OS X

Accessories

Cables for your camera model

Lenses for your camera model

Additional accessories for your camera model

Spectral Response

PYTHON NOIP1SN1300A Spectral Response (From Sensor Data Sheet)

The spectral response curve excludes lens characteristics and light source characteristics.

Mechanical Specifications

Camera Dimensions and Mounting Points

Mechanical Dimensions (in mm) for Cameras with C-mount Lens Mount

Maximum Allowed Lens Intrusion

→ See Maximum Allowed Lens Intrusion.

Stress Test Results

→ See Stress Test Results.

Requirements

Environmental Requirements

Temperature and Humidity

Housing temperature during operation0–50 °C (32–122 °F)
Humidity during operation20–80 %, relative, non-condensing
Storage temperature-20–80 °C (-4–176 °F)
Storage humidity20–80 %, relative, non-condensing
Housing temperature according to UL 60950-1max. 70 °C (158 °F)
Ambient temperature according to UL 60950-1max. 30 °C (86 °F)

UL 60950-1 test conditions: no lens attached to camera; no heat dissipation measures; ambient temperature kept at 30 °C (86 °F).

Heat Dissipation

→ See Providing Heat Dissipation.

Electrical Requirements

DANGER

Electric Shock Hazard

WARNING

Fire Hazard

NOTICE

Incorrect voltage can damage the camera.

Camera Power

NOTICE

Dual camera power supply can damage the camera.

  • Power supply via Power over Ethernet (PoE):  Power must comply with the IEEE 802.3af specification.

  • Power supply via I/O connector: The operating voltage is 12–24 VDC. As a minimum, 10.8 VDC must be supplied. To avoid damaging the camera, a maximum of 30 VDC must not be exceeded.

Opto-Coupled I/O Input Line

Voltage

Description

30 VDC

Absolute maximum. This voltage must never be exceeded. Doing so may damage the camera and voids the warranty.

0–24 VDC

Safe operating range.

0–1.4 VDC

Indicates a logical 0 (with inverter disabled).

>1.4–2.2 VDC

Region where the logic level transition occurs; the logical state is not defined in this region.

>2.2 VDC

Indicates a logical 1 (with inverter disabled).
  • Minimum current: 5 mA

  • Current draw: 5–15 mA

  • If the camera is connected to a PLC device, Basler recommends using a cable that adjusts the voltage level of the PLC to that of the camera.

Opto-Coupled I/O Output Line

Voltage

Description

30 VDC

Absolute maximum. This voltage must never be exceeded. Doing so may damage the camera and voids the warranty.

3.3–24 VDC

Safe operating range.

<3.3 VDC

Unreliable I/O output.
  • Leakage current: <60 µA. Actual leakage depends on operating temperature and production spread of electronic components.

  • Maximum load current: 50 mA

  • Minimum load current: Not specified. Consider the following:

    • Leakage current will have stronger effect when load currents are low.

    • Propagation delay of the output increases as load currents decrease.

    • Higher-impedance circuits tend to be more susceptible to EMI.

    • Higher currents cause higher voltage drops in long cables.

General Purpose I/O Lines

NOTICE

Applying incorrect electrical signals to the camera’s GPIO line can severely damage the camera.

Operation as Input

Voltage

Description

30 VDC

Absolute maximum. This voltage must never be exceeded. Doing so may damage the camera and voids the warranty.

0–5 VDC

Safe operating range. The minimum external pull-up voltage is 3.3 VDC.

0–0.8 VDC

Indicates a logical 0 (with inverter disabled).

>0.8–2 VDC

Region where the logic level transition occurs; the logical status is not defined in this region.

>2 VDC

Indicates a logical 1 (with inverter disabled).
  • Current draw (high-level): <100 μA

  • Sink current: Your application must be able to accept 2 mA sink current from the GPIO input line without exceeding 0.8 VDC.

Operation as Output

Voltage

Description

30 VDC

Absolute maximum. This voltage must never be exceeded. Doing so may damage the camera and voids the warranty.

3.3–24 VDC

Safe operating range.

<3.3 VDC

Unreliable GPIO output.
  • Internal pull-up resistor: ≈2 kΩ, with open collector. Many applications will have to provide an additional pull-up resistor.

  • Residual voltage ("on" state): ≈0.4 V at 50 mA and 25 °C  (77 °F) housing temperature. Actual residual voltage depends on operating temperature, load current, and production spread of electronic components.

  • Leakage current: <60 µA. Actual leakage depends on operating temperature and production spread of electronic components.

  • Maximum load current: 50 mA

  • Minimum load current: Not specified. However, consider the following:

    • Leakage current will have a stronger effect when load currents are low.

    • Propagation delay of the output increases as load currents decrease.

    • Higher-impedance circuits tend to be more susceptible to EMI.

    • Higher currents cause higher voltage drops in long cables.

Circuit Diagrams

→  See Circuit Diagrams for Basler ace Cameras.

Cable Requirements

Ethernet Cable

  • Use a high-quality Ethernet cable. Use of shielded CAT 5E or better cables with S/STP shielding is recommended.

  • Use either a straight-through (patch) or a cross-over Ethernet cable.

  • As a general rule, applications with longer cables or applications in harsh EMI conditions require higher category cables.

  • Close proximity to strong magnetic fields should be avoided.

  • Basler recommends using Ethernet cables from the Basler Vision Componentsrange.

I/O Cable

  • The I/O cable must be shielded.

  • The I/O cable must have a cross-section at least 0.14 mm² (close to AWG26).

  • Use twisted pair wire cables.

  • Maximum recommended cable length: 10 m

  • Camera-side connector: Hirose micro plug (part number HR10A-7P-6S) or equivalent

  • Close proximity to strong magnetic fields should be avoided.

  • If you are supplying power to the camera via Power over Ethernet, the I/O cable will not be used to supply power. However, you can still use the cable to connect to the I/O lines.

  • Basler recommends using I/O cables from the Basler Vision Components range:

    • GPIO cable, 10 m (yellow cable): For use with the GPIO lines of your camera. Also provides camera power. To avoid interferences due to crosstalk, the opto-coupled I/O lines are not connected.

    • Opto-I/O cable, 10 m (blue cable): For use with the opto-coupled I/O lines of your camera. To avoid interferences due to crosstalk, the GPIO lines are not connected. Does not provide camera power. Therefore, when using this cable, you must provide power via Power over Ethernet (PoE).

    • Opto-GPIO Y-cable, 2 x 10 m (yellow-blue cable): Allows you to use the GPIO lines and the opto-coupled I/O lines simultaneously without interferences due to crosstalk. There are two separate wires to split both I/O types. Also provides camera power.

    • Power-I/O cable, 10 m (gray cable): For use with the opto-coupled I/O lines of your camera. Unlike the opto-I/O cable (blue cable, see above), this cable allows you to provide camera power. However, because all lines are connected, crosstalk between the GPIO lines and the opto-coupled I/O lines may occur.

    • Power-I/O PLC+ cable, 10 m (gray cable): For use with the opto-coupled I/O lines of Basler cameras connected to a programmable logic controller (PLC). It adapts the signal level for zero voltage from PLC level (<8.4 VDC) to TTL level (<1.4 VDC).

Physical Interface

Camera Connectors

acA1300-75gm

NOTICE

Dual power supply can damage the camera.

Connector

Description

Ethernet connector
  • 100/1000 Mbit/s Ethernet connection to the camera

  • If power is not supplied via I/O connector: Power over Ethernet (PoE)

  • 8-pin RJ-45 jack
    Recommended mating connector: 8-pin RJ-45 plug (snap-in or with locking screws)

  • When using locking screws, note the horizontal orientation of the screws.

I/O Connector
  • If power is not supplied via Power over Ethernet (PoE): Power supply

  • Hirose micro receptacle (part number HR10A-7R-6PB)
    Recommended mating connector: Hirose micro plug (part number HR10A-7P-6S)

Connector Pin Numbering and Assignments

acA1300-75gm

PinLineFunction
1-12–24 VDC Camera Power
2Line 1Opto-coupled I/O input line
3Line 3General purpose I/O (GPIO) line
4Line 2Opto-coupled I/O output line
5-Ground for opto-coupled I/O lines
6-Ground for camera power and GPIO lines


相关标签:acA1300-75gm

最近浏览:

相关产品:

相关新闻:

在线客服
分享 一键分享
欢迎给我们留言
请在此输入留言内容,我们会尽快与您联系。
姓名
联系人
电话
座机/手机号码
邮箱
邮箱
地址
地址